or
| Line for review? | Supervisor for this pipe? | Does DCP operate this pipeline? | Active or idle status? | Trunk line or lateral? | Current operating pressure in PSIG? | Current volume in MMscfd? | Is there a sole producer on this line? | Can MAOP be significantly lowered? | Is this line on a pigging schedule? | Does this line have a history of liquids? | Sour gas operation? | Leaks in previous 2 years? | Any change in operating conditions in past 2 years? |
Any conditions on this pipeline that may require further assessment? |
Is there any other information about this line that could affect its operation? ie special project, changes in development nearby, loss of cover. etc |
Comments (if any)? | Mileage | Dia |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
EF-1 MALEK
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 20.001+ | No | No | Yes | Yes | No | 0 | No | No | No | 13.3 | 12 | |
| Line for review? | Supervisor for this pipe? | Does DCP operate this pipeline? | Active or idle status? | Trunk line or lateral? | Current operating pressure in PSIG? | Current volume in MMscfd? | Is there a sole producer on this line? | Can MAOP be significantly lowered? | Is this line on a pigging schedule? | Does this line have a history of liquids? | Sour gas operation? | Leaks in previous 2 years? | Any change in operating conditions in past 2 years? |
Any conditions on this pipeline that may require further assessment? |
Is there any other information about this line that could affect its operation? ie special project, changes in development nearby, loss of cover. etc |
Comments (if any)? | Mileage | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ | ------ |
| Line for review? | Supervisor for this pipe? | Does DCP operate this pipeline? | Active or idle status? | Trunk line or lateral? | Current operating pressure in PSIG? | Current volume in MMscfd? | Is there a sole producer on this line? | Can MAOP be significantly lowered? | Is this line on a pigging schedule? | Does this line have a history of liquids? | Sour gas operation? | Leaks in previous 2 years? | Any change in operating conditions in past 2 years? |
Any conditions on this pipeline that may require further assessment? |
Is there any other information about this line that could affect its operation? ie special project, changes in development nearby, loss of cover. etc |
Comments (if any)? | Mileage | Dia | Comments |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CC-3 HORDES CREEK NORTH
|
Steven Koehne | Yes | Active | Trunk line into or out of plant/booster | 0-125 | 0.001-1 | No | No | No launcher/receiver | No | No | 0 | No | No | No | 8.6 | 8 | Recorded 9 leaks in PODS | |
|
CC-4 ZOCK-KAUFFMAN 8"" LATERAL
|
Steven Koehne | Yes | Active | Lateral line | 0-125 | 0.001-1 | No | No | No launcher/receiver | No | No | 0 | No | No | No | 5 | 8 | Recorded 1 leaks in PODS | |
|
VI-1-EXT NORTH DUAL MAINLINE
|
Steven Koehne | Yes | Active | Trunk line into or out of plant/booster | 0-125 | 0.001-1 | No | No | No volume to move pig | No | No | 0 | No | No | No | 1.6 | 8 | Total line 9.3 with 4', 6" | |
|
CC-5 JOHNNY BEAUCHAMP LATERAL 8"" and 6""
|
Steven Koehne | Yes | Idle | Lateral line | 0-125 | 0 | No flow | No | No volume to move pig | No | No | 0 | No | No | No | 2.2 | 8 | Only Flange is 8", rest of the line is 6" | |
|
CC-6 MARSHALL LATERAL TO CABEZA
|
Steven Koehne | Yes | Idle | Lateral line | 0-125 | 0 | No flow | No | No volume to move pig | No | No | 0 | No | No | No | 3.7 | 8 | 2 recoreded leaks in PODS | |
|
CC-7 GRUTZMACHER 8"" LATERAL
|
Steven Koehne | Yes | Idle | Lateral line | 0-125 | 0 | No flow | No | No volume to move pig | No | No | 0 | No | No | No | 3 | 8 | 2 recoreded leaks in PODS | |
|
FT-1-EXT-2-RR Fintex to Trunkline 10"" Reroute
|
Josh Jurecek | Yes | Idle | Trunk line into or out of plant/booster | 0-125 | 0 | No flow | No | No volume to move pig | No | No | 0 | No | No | No | 0.6 | 10 | ||
|
FT-1-EXT-2 COY CITY TO REFUGIO
|
Josh Jurecek | Yes | Idle | Trunk line into or out of plant/booster | 0-125 | 0 | No flow | No | No volume to move pig | No | No | 0 | No | No | No | 52 | 10 | 3 recorded leaks in PODS | |
|
VI-1-17-2-1 8"" FROM WRIGHT MAT. TO PREWITT SITE
|
Steven Koehne | SOLD | Idle | Trunk line into or out of plant/booster | 0-125 | 0 | No flow | No | No volume to move pig | No | No | 0 | No | No | No | DCP no longer owns this pipe | 4 | 8" | |
|
VI-1-7-1 VI-1-7-1
|
Steven Koehne | SOLD | Idle | Trunk line into or out of plant/booster | 0-125 | 0 | No flow | No | No volume to move pig | No | No | 0 | No | No | No | DCP no longer owns this pipe | |||
|
VI-1-7-4 VENTEX SCHENDEL
|
Steven Koehne | SOLD | Idle | Trunk line into or out of plant/booster | 0-125 | 0 | No flow | No | No volume to move pig | No | No | 0 | No | No | No | DCP no longer owns this pipe | |||
|
WHA-4-3-4 COUEY LATERAL
|
Steven Koehne | Yes | Idle | Trunk line into or out of plant/booster | 0-125 | 0 | No flow | No | No volume to move pig | No | No | 0 | No | No | No | 0.8 | 8 | 4" is 0.33 miles is connected to this line | |
|
WL-2 MOBIL - LA GLORIA PLANT 8"" LINE / HPL LINE
|
Josh Jurecek | Yes | Idle | Trunk line into or out of plant/booster | 0-125 | 0 | No flow | No | No launcher/receiver | No | No | 0 | No | No | No | ||||
|
WHA-2 DOW 8 INCH SALES
|
Steven Koehne | Yes | Idle | Trunk line into or out of plant/booster | 0-125 | 0 | No flow | No | No volume to move pig | No | No | 0 | No | No | No |
| Line for review? | Supervisor for this pipe? | Does DCP operate this pipeline? | Active or idle status? | Trunk line or lateral? | Current operating pressure in PSIG? | Current volume in MMscfd? | Is there a sole producer on this line? | Can MAOP be significantly lowered? | Is this line on a pigging schedule? | Does this line have a history of liquids? | Sour gas operation? | Leaks in previous 2 years? | Any change in operating conditions in past 2 years? |
Any conditions on this pipeline that may require further assessment? |
Is there any other information about this line that could affect its operation? ie special project, changes in development nearby, loss of cover. etc |
Comments (if any)? | Column1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
EF-1-1-1-1 CGP 51 12"" Lateral
|
Josh Jurecek | Yes | Active | Lateral line | 701+ | 0 | Yes | No | No | No | No | 0 | No | No | No | Pioneer offload to DCP | |
|
SJ-1-5 (12"" NEW TAITON LAT) - (LINE 102)
|
Steven Koehne | Yes | Active | Lateral line | 351-700 | 0.001-1 | No | No | Yes | Yes | No | 0 | No | No | No | 2 segments became regulated | |
|
WHA-1 NAISER
|
Steven Koehne | Yes | Active | Trunk line into or out of plant/booster | 351-700 | 0.001-1 | No | No | No | No | No | 0 | No | No | No | ||
|
WHA-1-EXT NAISER
|
Steven Koehne | Yes | Active | Trunk line into or out of plant/booster | 351-700 | 0.001-1 | No | No | No | No | No | 0 | No | No | No | ||
|
WHA-1-EXT-2 NAISER
|
Steven Koehne | Yes | Active | Trunk line into or out of plant/booster | 351-700 | 0.001-1 | No | No | No | No | No | 0 | No | No | No | ||
|
SJ-1-8 COASTAL LATERAL
|
Steven Koehne | Yes | Active | Lateral line | 351-700 | 0.001-1 | Yes | No | No launcher/receiver | No | No | 0 | No | No | No | Producer Hillcorp | |
|
EF-1-1-1-3-1-4 Murphy Oil Ralph Edwards Saylee
|
Josh Jurecek | Yes | Active | Lateral line | 701+ | 0.001-1 | Yes | No | Non flowing for full pig route | Yes | No | 1-3 | No | No | No | Murphey Oil Producer | |
|
EF-2-3-2 Sabine Oil T-Bird
|
Josh Jurecek | Yes | Active | Lateral line | 701+ | 0.001-1 | Yes | No | No launcher/receiver | No | No | 0 | No | No | No | Formerly Sabine Producer | |
|
EF-2-3-3 Sabine Oil Kozielski
|
Josh Jurecek | Yes | Active | Lateral line | 701+ | 0.001-1 | Yes | No | No | Yes | No | 0 | No | No | No | Formerly Sabine Producer | |
|
XM-1 18E-100
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 0.001-1 | No | No | No | Yes | No | 0 | No | No | No | ||
|
XM-1-EXT 18E-100
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 0.001-1 | No | No | No | No | No | 0 | No | No | No | Blinded north west of Christmas liquid handling station. In service south east | |
|
WL-1-1 ENCINITAS LATERAL
|
Josh Jurecek | Yes | Active | Lateral line | 701+ | 0.001-1 | No | No | No launcher/receiver | No | No | 0 | No | No | No | ||
|
SJ-1-11 ORCHARD 12"" LATERAL - (LINE 118)
|
Steven Koehne | Yes | Active | Lateral line | 351-700 | 1.001-5 | No | No | No launcher/receiver | Yes | No | 0 | No | No | No | ||
|
WXG-4 10"" LINE
|
Steven Koehne | Yes | Active | Trunk line into or out of plant/booster | 351-700 | 1.001-5 | No | No | No | No | No | 0 | No | No | No | ||
|
ST-1-1-3 SHELL JAVALINA
|
Josh Jurecek | Yes | Active | Lateral line | 701+ | 1.001-5 | Yes | No | No launcher/receiver | No | No | 0 | No | No | No | Merit producer | |
|
BH-1-2 MC ALLEN RANCH TO SHELL PLANT 10"
|
Josh Jurecek | Yes | Active | Lateral line | 701+ | 1.001-5 | No | No | No launcher/receiver | No | No | 0 | No | No | No | ||
|
BH-1-6 10"" - CELANESE LATERAL
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 1.001-5 | No | No | No launcher/receiver | No | No | 1-3 | No | No | No | ||
|
BH-1 12"" MAINLINE - ARCO TO MC ALLEN RANCH 12"" PIPLEINE
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 1.001-5 | No | No | No launcher/receiver | No | No | 0 | No | No | No | ||
|
BH-1-EXT TEX - LINE 12"" - MAINLINE EXT.
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 1.001-5 | No | No | No launcher/receiver | No | No | 0 | No | No | No | ||
|
SRS-1 10"" Seeligson Return
|
Josh Jurecek | Yes | Active | Lateral line | 701+ | 1.001-5 | No | No | No launcher/receiver | No | No | 0 | No | No | No | Active until END STATION-60,119.4; Abandoned from there on | |
|
LO-20 THREE RIVERS TO KARON 8"" LOOP
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 10.001-20 | No | No | No volume to move pig | Yes | No | 1-3 | No | No | No | ||
|
LO-9 KARON 8"" (BEE CO LINE TO PETTUS PLANT)
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 10.001-20 | No | No | No volume to move pig | Yes | No | 1-3 | No | No | No | ||
|
LL-2 LL South 12"" Extention
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 351-700 | 5.001-10 | No | No | No launcher/receiver | No | No | 0 | No | No | No | ||
|
ST-1 MAIN LINE
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 5.001-10 | No | No | No launcher/receiver | Yes | No | 1-3 | No | No | No | Package #23 | |
|
BH-1-EXT-2 TEX LINE 8"" - MAINLINE
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 5.001-10 | No | No | Flow issues | No | No | 0 | No | No | No | Potential to loop and abandon/divest | |
|
ST-2-1 TRANSCO CARTER RANCH LAT.
|
Josh Jurecek | Yes | Active | Trunk line into or out of plant/booster | 701+ | 5.001-10 | No | No | No launcher/receiver | No | No | 0 | No | No | No | Could be removed due to being looped (MJ) |